Journal: Scientific Reports
Article Title: Defect detection by multi-axis infrared process monitoring of laser beam directed energy deposition
doi: 10.1038/s41598-024-53931-2
Figure Lengend Snippet: Experimental setup and example images from the manufacture of a 30° intersecting wall sample. ( a ) Installation of thermal cameras on TRUMPF deposition head with machine coordinate axes superimposed. The primary components are numbered: (1) CLAMIR camera with water cooling and data cable connected. (2) Coaxial mounting port for CLAMIR camera. (3) Optris PI 05M thermal camera, with data cable, at 55° to the k-axis. Attached via side-mounted bracket. (4) Coaxial powder nozzle for DED-LB/M. (5) Optris PI 1M thermal camera, with data cable, at 55° to the k-axis. Attached via rear-mounted bracket. (6) Stabilisation brace for side-mounted bracket. ( b ) Greyscale image obtained from CLAMIR camera. ( c ) Thermographic image obtained from Optris PI 1M camera. ( d ) Thermographic image obtained from Optris PI 05M camera.
Article Snippet: The first off-axis camera is the Optris PI 1M camera which monitors wavelengths in the 0.85–1.1 μm range and has a maximum measured temperature range of 450–1800 °C.